Domain 1: Q715-Motor Plants

Question 1

A six-cylinder diesel has essentially equal compression pressures in all cylinders. At a steady load, however, No. 4 has much lower firing pressure and a markedly cooler exhaust than the other five. All six share one turbocharger and charge-air receiver. Which fault best fits this pattern?

Show answer & explanation

Correct answer: B - Restricted delivery at the No. 4 injector

Question 2

During a steady watch, differential pressure across the duty lube-oil filter rises above the specified changeover setting. Oil temperature, downstream pressure, and bearing temperatures remain within limits. The clean standby chamber is filled, vented, and pressure-equalized; the duplex filter permits changeover while running. What is the appropriate response?

Show answer & explanation

Correct answer: C - Change to the clean chamber and monitor downstream pressure.

Question 3

With an air-started diesel running and its starting command off, one cylinder starting-air branch becomes abnormally hot near the cylinder. The other branches remain cool. This localized heating most strongly indicates:

Show answer & explanation

Correct answer: D - Combustion gas escaping past the cylinder starting-air valve.

Question 4

Steam demand rises abruptly on an auxiliary boiler. Drum pressure falls, measured steam flow exceeds feedwater flow, and both the gauge glass and independent level transmitter initially show a rising level. Boiler-water chemistry remains within operating limits. How should this apparently contradictory level rise be interpreted?

Show answer & explanation

Correct answer: D - Steam-bubble expansion is raising the level while water inventory decreases.

Domain 2: Q716-Engineering Safety & Environmental Protection

Question 5

Fuel spray has ignited in an enclosed engine room. Fuel has been isolated remotely, all personnel are accounted for outside, and release of the fixed total-flooding CO2 system has been ordered. The supply and exhaust fans are still running. Before releasing CO2, the engineer must:

Show answer & explanation

Correct answer: A - Stop ventilation and close the engine-room fire dampers.

Question 6

A semisubmersible is afloat at a displacement of 18,000 tonnes. At this draft, KM is 14.4 m and KG is 12.9 m; the total free-surface moment is 9,000 tonne-metres. The approved minimum corrected GM for this loading condition is 0.8 m. Checking only that GM criterion, which result should be recorded?

Show answer & explanation

Correct answer: A - 1.0 m; meets the stated GM minimum.

Question 7

An actively drilling MODU operates under a National Pollutant Discharge Elimination System (NPDES) permit. Its machinery-space separator produces effluent containing 12 ppm oil. A technician argues that being below 15 ppm automatically permits overboard discharge. What determines whether the proposed discharge is authorized?

Show answer & explanation

Correct answer: A - The applicable discharge conditions in the NPDES permit.

Domain 3: Q717-General Subjects

Question 8

Two identical alternators run in parallel on a 60-Hz bus. Each supplies 500 kW, but No. 1 supplies 350 kVAr and No. 2 supplies 50 kVAr. Bus voltage is correct and neither machine is overloaded. Using their manual load-sharing controls, how should the engineer equalize reactive load without changing the real-power split?

Show answer & explanation

Correct answer: D - Reduce No. 1 excitation and increase No. 2 excitation.

Question 9

For R407C at the measured evaporator-outlet pressure, the saturation chart gives a dew point of -8°C and a bubble point of -13°C. The line temperature at that same point is +10°C. Evaporator airflow and condenser-outlet subcooling are normal, but a substantial temperature drop is localized across the liquid-line filter-drier. Which assessment is supported?

Show answer & explanation

Correct answer: C - 18 K superheat; investigate a restricted filter-drier.

Question 10

An operating centrifugal seawater pump develops a gravel-like noise. Delivery falls while the suction gauge shows increasing vacuum. The sea chest remains submerged, seawater temperature is unchanged, and motor speed is steady. The most useful first inspection is for:

Show answer & explanation

Correct answer: B - An obstructed seawater suction strainer.

That's 10 of 1,030

The full bank has 1,020 more AE MODU questions with explanations.

Continue in the free practice test →

View plans